YVG-12 Quod est anulum electrica velit principale unitatis switchgear nobis switchgear market
YVG-12 Quod est anulum electrica velit principale unitatis switchgear nobis switchgear market
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YVG-12 Quod est anulum electrica velit principale unitatis switchgear nobis switchgear market
Picture
  • YVG-12 Quod est anulum electrica velit principale unitatis switchgear nobis switchgear market
  • YVG-12 Quod est anulum electrica velit principale unitatis switchgear nobis switchgear market

YVG-12 Quid est anulum electrica principale uni...

1. ONERO praesidio
2. Brevi circuitu praesidio
3. Controlling
4. In residentialibus aedificationibus, non residentialibus aedificiis, industria fons industriae et infrastructuris usus est.
5. Secundum genus emissio instantaneae sic indicatur: genus B (3-5)ln, genus C (5-10)ln, genus D (10-20) ln

Contact Us

Product Details

Medium Voltage Switchgear
YVG-12 Solidum Insulation Ring Network Cabinet

YVG-12 series solida insulationis anulus retiarii switchgear est plene insulatum, plene obsignatum, et liberum solidae insulationis vacuum switchgear sustentationem.
Arcae retis anulus characteres simplicis structurae, operationis flexibilis, certae interlocking, et accommodatae institutionis habet, et ad 50Hz, 12 kV systemata virtutis apta est. Late in retibus anulis industrialibus et civilibus, ac retis terminalibus inceptis distribuendis, pro instrumento recipiendi et distribuendi electricitatem, praesertim ad urbanam distributionem residentialem, industrialem et fodiendarum conatum adhibitum in aliquet nisl, subway, venti vim generationis, cuniculis, et aliis locis.
Apta ad usum in locis asperis ambitibus, ut altitudinis, altitudinis, caliditatis, caloris humidi, pollutionis gravis, etc.
Signa: IEC62271 - 1 -200 IEC62071 -2000 -2003

 

Electio

1

Per signa functionis in systematis: ineuntes scrinium, exeuntis armarium, armarium buscum, arca metering, TP scrinium, armarium elevatum, etc., per numerum schematis designatur wiring. Secundum genus switch components principalis, est
divisum in: onus switch scrinium, onus transibit fuse iunctura scrinium electrica, arcae ambitus ruptor, et solitudo scrinium transitum, etc., repraesentatum per F (coniunctio electrica appliance fuse), V (ruptor circi), C (onus switch), etc.

Conditiones operating

1. Temperatura ambiens: Non plus quam +45℃, non minus quam -45°℃. Mediocris temperatura non plus quam +35℃ intra 24 horas. 2. Altitude: Non plus quam 3000m.
3. Relativum Umor: mediocris valor cotidianus plus quam 95% est, mediocris menstrua pretii non plus quam 90% est. 4. Terrae motus magnitudo: Non plus quam VIII gradus.
5. Vapor Pressura: mediocris valor cotidianus plus quam 2.2kPa est, et mediocris menstrua pretii non plus quam 1.8kPa est. 6. Institutionum locorum sine igne, explosione periculi, pollutione gravi, corrosio chemica et tremore violento.

Technica notitia

Item Unitas C OMNIBUS F OMNIBUS V Module
Onus switch Onus switch cum fuse Vacuum switch Disconnector / Earthing Switch
Rated voltage kV 12 12 12 12
Ratum frequency1min Hz 50/60 50/60 50/60 50/60
Potentia frequency voltage in 1 min sustinere kV 42/48 42/48 42/48 42/48
Fulmen impetus sustinere voltage (Peak) kV 75/85 75/85 75/85 75/85
Ratum current A 630 note1) 630 /
Rated clausa loop fractionis current A 630 / / /
Rated funem præcipiens fractionis current A 10 / / /
Ratum ambitum brevem currentem faciens A 50 80 50 50
Rated apicem sustinere current kA 50 / 50 /
Rated breve tempus sustinere current kA/3S 20 / 20 /
Ratum brevis circuitio praevaricationis current kA / 31.5 20 /
Ratum translatio current A / 1700 / /
Maximilianus. de current rated fuse A / 125 / /
resistentia loop μΩ ≤200 ≤500 / /
Mechanica vita temporibus 5000 3000 5000 2000

Nota: I) Pendet rated current ex fuse

Feature

1. YVG- 12 switchgear principaliter tres habet unitates functiones, nempe V unitas (conruptor unitatis), C unitas (onus transitum unitas), F unitas (electrica unita unita), cum ratio plures unitates configurari postulat, arbitratu esse potest. dilatatur in dextra parte dextra, et ad libitum disponi potest secundum diversas technas consiliorum diversorum
configuratione requisita.
2. Quaelibet unitas constitutione in tres partes dividitur: instrumentum camerae, mechanismum et ambitum primarium operans. The
instrumentum cubiculum instrui potest cum praesidio microcomputer (intelligentis moderatoris) aliisque metris. Mechanismus operans est specialis operatio fons mechanismus, quae etiam instrui potest additis electricis operantibus
mechanismus, primus ambitus technologiam globorum activitatis APG adoptat, et vectis bus, transitum et arc- tios separatum
camera exstinguenda sunt omnino signata in epoxy resinae, et speciales sunt articulis clausuris connexis.
3. YVG- 12 solida velit commutatio commoda structurae compactae, insulae plenae, longae vitae, sustentationis liberae, exigui spatii occupatio, salus et commendatio, nec ambitu laboranti afficitur. In retis industrialibus et civilibus anulis copia etterminalis potentiae late adhibetur.

 

Design design

2

Altiore et ascendens dimensiones (mm)

3

442×845×1550(W*D*H)
circa ruptor

442×845×1550(W*D*H)
onus confractus switchgear "

4

442×845×1550(W*D*H)
onus confractus switch-fuse combination
switchgear

750×845×1550(W*D*H)
x metering switchgear
(Solidae insulatas aliasque desidia genus)

5

750×845×1550(W*D*H)
metering switchgear
(Northmanni genus)

442×845×1550(W*D*H)
Elevatio switchgear

6

442×845×1550(W*D*H)
TP switchgear cum disconnector
(Solidae insulatas aliasque desidia genus)

600×845×1550(W*D*H)
TP switchgear sine disconnector
(Northmanni genus)

7

442×845×1550(W*D*H)
disconnector switchgear

884×845×1550(W*D*H)

Elevatio switchgear

Epistulam tuam hic scribe et mitte nobis