YCB7RL-100 Electromagneticum RCCB
YCB7RL-100 Electromagneticum RCCB
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

YCB7RL-100 Electromagneticum RCCB
Picture
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB
  • YCB7RL-100 Electromagneticum RCCB

YCB7RL-100 Electromagneticum RCCB

General
YCB7RL-100 seriei electromagneticae residua vena operata circa ruptor ruptor maxime conveniens est pro AC distributione reticulorum cum aestimata intentione laborantis 230V vel 400V ad 50Hzand currentis aestimationis 63A. Usus ad indirectam contactum tutelam hominum, et etiam adhiberi potest ad prohibendos casus ignis per velit damnum in circuitus et apparatum, resultans in reatu culpae excursus.

Contact Us

Product Details

General

YCB7RL-100 series electromagneticae currentis residualis circa ruptor operati maxime convenit ad retiacula AC distributionis cum intentione aestimata operis 230V vel 400V in 50Hz et pro currenti aestimationis 63A. Usus ad indirectam contactum tutelam hominum, adhiberi potest etiam ad prohibendum. pericula ignis causantur ex velit damnum in circuitibus et instrumentis, consequens est culpa excursus terrae.

Feature

Praesidium contra effectibus sinusoidis alternantis terrae culpae currentium. Tutela lacus tutelae non requirit copiam potentiae auxiliaris. Non afficitur fluctuationes voltages in potentia eget.

Electio

YCB7RL   100 1P+N 63 100mA Type
Modus   Testa gradus
current
Pole Ratum current Rated residua
operating current
Type
RCCB
Electromagnetic
  100 1P+N
3P+N
6
10
16
20
25
32
40
50
63
Default:
30mA
100mA
300mA
Default: AC Type A Type

 

Technical data

Model YCB7RL-100
Electrical
features
Genus ultrices   Genus electromagneticum
In current rated A 6,10,16,25,32,40,50,63,80,100
Typus (unda forma terrae lacus sentitur)   A, AC
Poloni P 1P+N,3P+N
Rated voltage Ue V 230/400
Nulla voltage Ui V 500
Rated frequency Hz 50/60
Rated fractionis facultatem Inc=I△c A 600,010,000
Ratum impetus sustinere intentione (1.2/50) Uimp V 6000
Dielectric test voltage ad ind.Freq.for 1min Kv 2.5
Rated sensus I△n A 0.03,0.1,0.3
Ratum residua faciendi et frangendi facultatem lAm A 500(In≤40A);630(In=50A/63A);
Pollutio gradus   2
Vita electrica t 4000
Mechanica
features
Mechanica vita t 8000
Praesidium gradum   IP20
Repono temperatus -25~+70
Ambiens temperatus (cotidianis average≤35℃) -5~+40
Terminatio nexu generis   Cable/pin-type busbar/U-type busbar
Institutionem Terminatio magnitudinis top / imo ad funem mm² 25/35
Terminatio magnitudinis top / imo ad busbar AWG 18-3/18-2
tensus tensus mm² 10/16
AWG 18-8/18-5
Adscendens N*m 2.5
In-Ibs 22
Connection   On DIN rail EN 60715(35mm) per ieiunium fabrica
  A summo vel fundo

YCB7RL-100 BOOK_00

Epistulam tuam hic scribe et mitte nobis

Related Products